Universal tension and compression load cells for industrial force measurement.
o Flat design
o High stiffness and fatigue resistant
o Highly resistant to transverse forces
o Complete range of mounting accessories available
o Material: stainless steel (2960)**, anodised aluminium alloy (2962), alloy steel (2965)
o Cable length: see drawing table - CL (other lengths available on request)
Accuracy class (-) - 0.25 % F.S. - 0.1% F.S. - 0.03 % F.S.
Combined error (non-linearity + hysteresis) (% F.S.*) - <± 0.25 - < ± 0.1 - <± 0.03
Repeatability error (% F.S.*) - <± 0.1 - <± 0.03 - <± 0.015
Creep error over 30 min. (% F.S.*) - <± 0.1 - <± 0.06 - <± 0.025
Reference temperature (°C) - 23 - 23 - 23
Temperature coefficient of the sensitivity (% F.S.*/10°C) - <± 0.05 - <± 0.05 - <± 0.015
Temperature coefficient of zero signal (% F.S.*/10°C) - <± 0.035 - <± 0.035 - 300 - >300 - >300
Permissible dynamic loading (% F.S.*) - 70 - 70 - 70