Our model 5000 is designed to measure a force or constraint, without any change to the mechanical structure, simply by replacing the clevis pin with our custom-made load pin.
o Protection class: IP65 (up to IP68: see options)
o Sturdy design
o Easy to install
o Complete range of CE certified electronics, load limiters and displays available for hoisting applications and lifts
o Cable length: 6 m (other lengths available on request)
Combined error (non-linearity + hysteresis) (% F.S.*) - 0.25 - 1 - 0.5 - 2 - 0.5 - 2
Repeatability error (% F.S.*) - <± 0.25 - <± 0.25 - <± 0.25
Creep error over 30 min. (% F.S.*) - <± 0.3 - <± 0.3 - <± 0.2
Zero shift after loading (% F.S.*) - <± 0.5 - <± 0.5 - <± 0.5
Reference temperature (°C) - 23 - 23 - 23
Temperature coefficient of the sensitivity (% F.S.*/10°C) - <± 0.2 - <± 0.2 - <± 0.2
Temperature coefficient of zero signal (% F.S.*/10°C) - 5000
Reference excitation voltage (VDC) - 10 - 10 - 10
Permissible nominal range of excitation voltage (VDC) - 3...12 - 3...12 - 3...12
Safe load limit (% F.S.*) - 150 - 200 - 300
Breaking load (% F.S.*) - > 300 - > 500 - > 1000
Permissible dynamic loading (% F.S.*) - 50 - 75 - 100
Static lateral force limit (% F.S.*) - 100 - 150 - 200