Customizable configuration (inputs/outputs), user interface and graphics
Receives and displays ARINC 429, analog, discrete, frequency, temperature, absolute and differential pressure data
Standard 2-inch size
Lightweight — 0.4 lbs
Simple user interface — Push-and-turn control knob
Daylight readable LCD and high-definition graphics
External lighting control and built-in photocell for automatic dimming
Field-upgradeable software via standard USB-A port
TSO-certified hardware and software (Design Assurance Level A)
Designed and built in Wichita, Kansas, USA
Two-year limited warranty
Data Inputs
ARINC 429 - Low or high speed; labels per individual CID
RS-232 - Data format per individual CID
Analog* - 0-28 VDC, 1% accuracy (±0.050 V)
Discrete* - Open, ground, high
Thermocouple - Type K
Frequency* - 0.5-100 V pk-pk; 10-2,000 Hz; 10-20,000 Hz (-1 only)
Pressure - Absolute/static and differential/pitot (-2 only)
*Up to 12 programmable Analog, Discrete or Frequency inputs available
Data Outputs
ARINC 429 - High speed; labels per individual CID
RS-232 - Data format per individual CID
Analog* - 0-5 VDC, 1% accuracy (±0.050 V)
Discrete* - Open, ground, high
*Up to 12 programmable Analog or Discrete outputs available