The 6580 & 6580-HA (High-Accuracy) Air Data Test Sets are rack-mount units with built-in pressure and vacuum pumps featuring quiet operation. These test sets can be used to test and calibrate altimeters, airspeed / Mach indicators, Climb indicators, Flight data recorders, Air data computers, and EPR indicators. The high accuracy of these units meets all RVSM requirements. Also, they need to be calibrated only once a year. The use of “Profiles” makes it possible for the operator to run through a test using only a single key on the front panel keypad of these units.
The 6580-M1 has a built-in output switching module (OSM) with 3 Static Ports and 3 Pitot Ports on the rear panel, which can individually be controlled (opened and closed) using external inputs.
Pressure function
Range:
0.1 to 42 inHg
0.1 to 38 inHg
0.1 to 42 inHg
Resolution:
0.001 inHg
0.0001 inHg
0.001 inHg
Accuracy:
±0.002 inHg
±0.001 inHg
±0.002 inHg
Units:
inHg, mbar
inHg, mbar
inHg, mbar
Altitude function
Range:
-4000 ft. to 100,000 ft.
-4000 ft. to 100,000 ft.
-4000 ft. to 100,000 ft.
Resolution:
1 foot
1 foot
1 foot
Accuracy:
± 2 ft. @ 0 ft.
± 6 ft. @ 35,000 ft.
± 12 ft. @ 50,000 ft.
± 50 ft. @ 80,000 ft.
± 1 ft. @ 0 ft.
± 3 ft. @ 35,000 ft.
± 6 ft. @ 50,000 ft.
± 25 ft. @ 80,000 ft.
± 2 ft. @ 0 ft.
± 6 ft. @ 35,000 ft.
± 12 ft. @ 50,000 ft.
± 50 ft. @ 80,000 ft.
Units:
Feet, Meters
Feet, Meters
Feet, Meters
Climb function
Range:
0 ft/min to ±50,000 ft/min
0 ft/min to ±50,000 ft/min
0 ft/min to ±50,000 ft/min
Resolution:
1 ft/min
1 ft/min
1 ft/min
Accuracy:
±1% of rate of climb
±1% of rate of climb
±1% of rate of climb