Standard flange design mounts directly to cylinders
Proprietary Interface temperature compensated strain gages
Performance to 0.05%
Eccentric load compensated
0.0008%/°F (.0015%/°C) temperature effect on output
Low deflection
Barometric compensation
Tension & compression
Fatigue Rated -100 million fully reversed cycles
The 1700 flange-mounted LowProfile™ load cell has multiple smaller threads, making installation easier for certain types of cylinders. The low-profile configuration of our fatigue-rated load cell provides up to 100million duty cycles. The gage sensors in every load cell are individually inspected and tested, and certified to meet our rigid standards. Formed from a unique alloy, our gages provide very low resistivity, for high signal;-to-noise ratios for demanding applications.