Temperature measurement utilizes a platinum RTD. Both wire wound and thin-film RTDs are available. Thin-film RTDs are used in applications requiring durability under high vibration, or where physical size is limited. The RTDs are potted into a stainless steel cover for strength and quick response.
Units are available with a wide range of welded connectors. Standard and fully custom interfaces are available. Body size and shape is suited for a wide variety of applications. Sensor can be used with any media compatible with stainless steel.
Operation -
Accuracy - IEC-751 Class A or B
Resistance @ 0°C - 100 ohm or 1K ohm
Max. Current - 2 mA recommended operating max (resistance output)
Recommended Current - 1 mA max (resistance output)
Electrical - RTD resistance output or amplified voltage or 4-20 mA output
Environmental -
Temperature Range - -100°C to +250°C standard, +300°C extended
Survival Temperature - -100°C to +500°C media temp
Vibration - 5 to 2000 Hz up to 20 g’s
Shock - 100 g’s
Service Life - 1000 temperature cycles
Weight - 5 oz. (approx.)