IDEAL FOR
PERFORMING INTERNAL LEAKAGE TESTS ACCORDING TO ITCAN / TARAN TEST PROCEDURES
FEATURES
Certified and listed in Boeing AMM
• Operation via touchscreen
• Set zero function with 4 x totalizing memory storage
• Printer for printing recorded data
• Automatic bypass in case of excessive flow
• Integrated calibration menu
• Hydraulic and electric components completely isolated from each other
• Heavy duty stainless steel frame with drip tray
• Mobile trolley on rigid and caster wheels
• Weatherproof cover for operator panel
• Doors for easy maintenance
Model Suitable for
HTT-01 All Airbus 3000psi, Boeing 747, 757, 767 and 777
HTT-02 Boeing 737 HTT-03 Airbus A350, A380 and Boeing 787
TECHNICAL DATA
GENERAL
Main power supply cable 5 meter
Hydraulic hose to A/C system 6 meter
HYDRAULIC
Automatic bypass suitable for 225 l/min
MEASUREMENT
High pressure gauge HTT-01 and HTT-02: 0 - 4000 psi
HTT-03: 0 - 6000 psi
Accuracy 1% of full scale
Temperature -25 - 100 °C
Accuracy 0,4% of full scale
Flowmeter Accuracy 0,3% of measured value
Readout in l/min, gpm or cc/min
POWER
Supply voltage 1Ph. 85-132 or 176-264 V (automatic range switchover)
Supply frequency 47-63 Hz
Current 1,2 A