Hename designed GP with the customers’ requirements in mind interviewing many ILS maintenance experts. One of our main goals with system design was to considerably reduce the complexity and amount of time the field engineer spends on their maintenance work. In addition the careful and thoughtful preparation in our factory is producing the fault free equipment.
Recognizing the need for a sustainable equipment running under harsh environment, we reflected every possible temperature compensation circuit on the systems.
Whether the airport is highly populated or less populated, our GP is sure to meet all demands. Upgrading from CAT I through CAT II to CAT III is very easy, every unit we are releasing from our factory is CAT III ready, supporting long term growth success.
System - Specification
Type - Dual Frequency (Fc ± 8 KHz) or Single Frequency
Frequency Range - 328.6 MHz to 335.4 MHz 150KHz spacing
Carrier Frequency Stability - ±0.0001%, 166Hz@332MHz
Operation Temperature - -10˚C to +55˚C
Relative Humidity - 0 ~ 90%
Primary Power - 110 V to 230V
47 to 63Hz
System and Standby Power - +24 V DC
Battery Backup - 4 hours or longer
Transmitter - Specification
CSB Output Power - Typically 5 Watt (+37 dBm)
Adjustable 32dBm to 40dBm
SBO Output Power - Typically 0.2 Watt (+23 dBm)
Adjustable 20dBm to 30dBm
CLR Output Power - Typically 0.5 Watt (+27 dBm)
Adjustable 24dBm to 34dBm
CSB/SBO Power Stability - ±0.2dBm
Harmonics / Spurious - 1uW / 10 uW
Total Harmonic Distortion - less than 1%
CSB/SBO Phase Adjustment - ±180 degree
Modulation - Frequency 90Hz±0.1%, 150Hz±0.1%
Modulation Depth 80% (0%~90%)
SDM Stability ±0.8%