GPU 140 kVA – 400Hz:
Power - 140 kVA
Voltage - 115/200 Vac
Voltage regulation - ± 1%
Power Factor - 0,8
Output 115/200Vac 400Hz - N°2 (70kVA)
Output 28,5Vdc - (Optional)
-------------------------------
ENGINES
FPT (IVECO):
Stage 0 (Model:N67SM1) - 18F/140TNE @1846rpm
Stage III (Model:N67TE1P) - 18F/140TE @1846rpm
Stage V (Model:N67TEVP04) 18F/140TEV @1846rpm
Cummins:
Stage III (Model:QSB 6.7) - 18C/120TE @1846rpm
Stage V (Model:B6.7) - 18C/120TEV @1846rpm
Deutz:
Stage V (Model:TCD6.1L6) - 18D/120TEV @1846rpm
------------------------------
ALTERNATOR
Power - 140 kVA
Authorized overload: 110% of rated load for 1 hour in a 6 hours period
300% of rated load for 20sec
------------------------------
AC OUTPUT
N° of outputs - 2 (70 kVA each)
Connection - 3 phase 4 wire
Voltage - 115/200Vac
Frequency 400 Hz
------------------------------
DC OUTPUT (Optional)
N° of outputs - 1 (28,5 Vdc)
------------------------------
CONTROL PANEL
Protection - IP 54
Measure:
Engine: oil pressure, water temperature, fuel level, speed, battery voltage, hour counter, alternator battery charger.
400Hz output: voltage, frequency, current, power kVA-kVAR-kW, Cosphi (measures phase to phase AND phase to neutral).
28Vdc output: voltage, current