- Runways, Taxiways - Ground Support >
- Aircraft ground support >
- AC ground power unit
AC ground power units
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 115, 200, 28 V
Frequency: 400 Hz
Power: 140, 90 kVA
Engine: Deutz / Cummins / John Deere Dimensions: 3300 x 1880 x 1790 mm Weight: 2700 kg The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. ...
GUINAULT S.A FRANCE
Voltage: 28, 115, 200 V
Frequency: 400 Hz
Power: 180, 90 kVA
... 165 kWh Dimensions: 3460 x 2130 x 1680mm Weight: up to 4100kg (depends on battery capacity) The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards ...
GUINAULT S.A FRANCE
Voltage: 115, 200 V
Frequency: 400 Hz
Power: 45 kVA
Engine: Deutz Dimensions: 2060 x 1430 x 1120 mm Weight: 1100 kg The Guinault GPUs provide power to the aircraft in accordance with aircraft manufacturers' recommendations and standards in force. They deliver an alternating ...
GUINAULT S.A FRANCE
Voltage: 114 V - 116 V
Frequency: 400 Hz
Power: 90 kVA
... Phase voltage displacement with balanced load 120°±2° Overload capacity 125%@5min, 150%@10s DC Power 17.1kw DC voltage 28.5V DC current 600 A (continuous) 2000A ...
Voltage: 29 V
... applied. The unit has a dual purpose: it provides 28.5VDC continuous power for avionics work and is used to start the aircraft or APU. This is the true GREEN GPU. The unit can operate ...
Voltage: 5 V - 30 V
... new GPU range for aircraft and helicopter users. Its wide GPU range for Aviation is composed of a lightweight continuous power supply (SA), a jump starter supply (SD) and a combination ...
Voltage: 115 V
Frequency: 400 Hz
Power: 45 kVA - 180 kVA
... that needs power. Performance: Superior performance compared to traditional fuel models, ensuring stable and reliable power for the aircraft during ground operations. Sustainability: ...
BERTOLI SRL
Voltage: 200 V
Frequency: 400 Hz
Power: 90 kVA
GPU 90 kVA – 400Hz: Power - 90 kVA Voltage - 115/200 Vac Voltage regulation - ± 1% Power Factor - 0,8 Output 115/200Vac 400Hz - N°1 Output 28,5Vdc - (Optional) ------------------------------- ENGINES FPT ...
BERTOLI SRL
Voltage: 200 V
Frequency: 400 Hz
Power: 60 kVA
GPU 60 kVA – 400Hz: Power - 60 kVA Voltage - 115/200 Vac Voltage regulation - ± 1% Power Factor - 0,8 Output 115/200Vac 400Hz - N°1 Output 28,5Vdc - Option ------------------------------- ENGINES FPT ...
BERTOLI SRL
Voltage: 29 V
Frequency: 400 Hz
The CT Series 400 Hz GPU (Ground Power Unit) features a brushless revolving field generator, rubber torsion axle-mounted of rugged galvanized steel construction with ...
Voltage: 26 V
Frequency: 60, 50 Hz
... four hours. When plugged into 110/220 Volt single phase AC power, PAC® Model 53050 is a 28.5 Volt continuous DC portable power supply . Continually delivering full ...
Voltage: 26, 28 V
... Indication - Digital to IP65 Auxiliary Protection - Circuit breaker 40A Auxiliary Input - 29V DC Aircraft Cable - 2 m heavy duty Charger - 8 Amp universal AC input charger. Charging ...
Voltage: 115, 200, 29 V
Frequency: 400 Hz
Power: 40, 90, 140, 60, 180 kVA
Ground Support Equipment for aircraft supplies power to a parked aircraft on ground through 200 / 115V 400Hz AC and / or 28.5V DC Voltages. This can ...
POWER FORCE TECHNOLOGIES PTE LTD
Voltage: 29 V
Our TC3000A range is simply a combination between our battery powered start units and our mains powered continuous power supply units. When plugged into ...
Red Box
Voltage: 115, 200 V
Frequency: 400 Hz
Power: 140, 120 kVA
The Self-Propelled Ground Power Unit, model EAA-100, 120 and 140 KVA’s, has been designed to provide electric current to all types of aircraft, both commercial and military, whose onboard ...
EINSA - EQUIPOS INDUSTRIALES DE MANUTENCIÓN
Voltage: 200, 415, 380, 28 V
Frequency: 400 Hz
Power: 30, 120, 90, 180 kVA
... 1.5%) and unit power factor (PF=1). That is ideal for military applications as we guarantee minimum impact on the mains or other power sources upstream. No Break Power ...
Sinepower
Voltage: 380 V - 415 V
Frequency: 50 Hz
Power: 90, 120, 140, 180 kVA
... display, on the unit front command and control panel. No emissions Max reliability Silent operation Significant savings on management and maintenance costs LCD touch screen display BATTERIES Lithium batteries ...
EFFETI S.R.L.
Voltage: 380 V - 480 V
Frequency: 400 Hz
Power: 20 kVA - 45 kVA
... aircraft ground power applications in the hangar or ramp area. The dual output AC/DC PwrKart provides simultaneous AC and DC power from a single GPU. ...
Voltage: 28, 26, 24 V
Frequency: 50, 60 Hz
... 300 is a 28V DC ground power unit, (GPU), designed for use in aircraft hangars, congested ramps and busy gate areas where space is limited. Regional and commuter operators ...
Voltage: 108 V - 118 V
Frequency: 380 Hz - 420 Hz
Power: 60 kVA - 180 kVA
FCX Systems, Inc. designs and manufactures 60-180KVA diesel generated 400HZ power units built for rugged demand, high performance and ease of operation. The performance and flexibility of this design is unparalleled.
Voltage: 230, 400 V
Frequency: 50 Hz
Power: 8, 10 kVA
World's highest specific output! Equipped with air intake silencer Optional add on exhaust muffler Propulsion: Turboshaft Engine PRO X Small - Lightweight - Powerful!
Voltage: 29 V
Frequency: 60, 50 Hz
... easily maneuver and operate the unit. Excellent for testing and troubleshooting (avionics, TMDE, electronics, and hydraulics). Will charge and condition vehicle batteries when unit is left connected ...
Tesla Industries, Inc.
Voltage: 115, 200, 28 V
Frequency: 400 Hz
Unit designed for supplying aircraft electrical systems with AC and DC power during engines starting and checking aircraft deck equipment on the ground. GPU ...
Voltage: 180, 115, 200, 220, 28 V
Frequency: 400, 50 Hz
Power: 10, 90 kVA
... -S distribution pillars are stationary power distribution units supplying 220/380V 50 Hz AC and 115/200V 400Hz special current to electrical loads found within the airport apron. These ...
ELECTROAIR
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how AeroExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining